Difference between revisions of "OSBYTE &49"
m (Added OSWORD.) |
(Fleshed out calls.) |
||
Line 1: | Line 1: | ||
[[Category:OSBYTE]] | [[Category:OSBYTE]] | ||
− | {{PageTitle|OSBYTE &49 (73) | + | {{PageTitle|OSBYTE &49 (73): Integra-B calls}} |
− | + | On entry: | |
− | + | X=&FF - returns X=&49 indicating Integra-B is present | |
− | + | On exit: | |
− | + | X=&49 - Integra-B is present | |
− | + | X=&FF - call unsupported | |
− | + | ||
+ | On entry: | ||
+ | X=&FE - initialise alarm | ||
+ | On exit: | ||
+ | ??? | ||
+ | |||
+ | On entry: | ||
+ | X=%0000mmtt - update RTCUpdateOptions | ||
+ | Options are set to (oldOptions AND mm) EOR tt | ||
+ | b0=Alarm generates a User Event | ||
+ | b1=Alarm generates Service Call &49 | ||
+ | If the options are set to non-zero, the RTC interupt enable is updated | ||
==See Also== | ==See Also== |
Latest revision as of 17:36, 30 November 2022
OSBYTE &49 (73): Integra-B calls
On entry: X=&FF - returns X=&49 indicating Integra-B is present On exit: X=&49 - Integra-B is present X=&FF - call unsupported On entry: X=&FE - initialise alarm On exit: ??? On entry: X=%0000mmtt - update RTCUpdateOptions Options are set to (oldOptions AND mm) EOR tt b0=Alarm generates a User Event b1=Alarm generates Service Call &49 If the options are set to non-zero, the RTC interupt enable is updated
See Also
- OSWORD &49 - Integra-B shadow memory calls
- OSBYTE &49 - Check for Integra-B shadow memory
- OSBYTE &6C - Select Master/Integra-B shadow memory
- OSBYTE &6F - Select Aries/Watford shadow memory
- OSBYTE &70 - Select memory for Master VDU access
- OSBYTE &71 - Select memory for Master video display
- OSBYTE &72 - Select future use of shadow memory
- OSBYTE &73 - Select shadow bank
- OSBYTE &74 - Check for Solidisk shadow memory
- Paging in video memory
- http://mdfs.net/Docs/Comp/BBC/Osbyte00