Difference between revisions of "OSWORD &0F"

From BeebWiki
Jump to: navigation, search
(PMS Clock)
(Added subcalls 3 and 6.)
Line 5: Line 5:
 
   XY?0=length of data at XY+1
 
   XY?0=length of data at XY+1
 
   XY?0=3  Set alarm XY+1=3-byte BCD alarm block
 
   XY?0=3  Set alarm XY+1=3-byte BCD alarm block
 +
  XY?0=3  Set timezone offset from XY+1="TZN"
 
   XY?0=5  Set from  XY+1=5-byte centisecond time
 
   XY?0=5  Set from  XY+1=5-byte centisecond time
 +
  XY?0=6  Set timezone offset from XY+1="TZN+NN" or XY+1="TZN-NN"
 
   XY?0=7  Set from  XY+1=7-byte BCD date block, year 1980-2079
 
   XY?0=7  Set from  XY+1=7-byte BCD date block, year 1980-2079
 
   XY?0=8  Set from  XY+1=8-byte BCD date block with century
 
   XY?0=8  Set from  XY+1=8-byte BCD date block with century
Line 19: Line 21:
 
implements the call, ''not'' the caller.
 
implements the call, ''not'' the caller.
  
On exit:
+
Where different subcalls have the same length byte, the calls are distinguished
  The only defined exit state is that unsupported calls should leave the control
+
by the data block being either BCD or text. For instance:
  block unchanged, and known implementations leave the control block unchanged
+
* 3,TIME - each byte is &00-&59 or &C0-&FF
  after successful calls. Known implementations also leave the control block
+
* 3,"TZN" - each byte is &40-&7F
  unchanged after unsuccessful calls.
+
* 8,DATETIME - byte XY?3 is BCD value &00-&1F
 
+
* 8,"hh:mm:ss" - byte XY?3 is printable character
  An appropriate extention would be for supported calls to modify the returned
+
 
  control block if passed invalid data, such as 8,"99:88:77" which is an invalid
+
===On exit:===
  time.
+
The only defined exit state is that unsupported calls should leave the control
 +
block unchanged, and known implementations leave the control block unchanged
 +
after successful calls. Known implementations also leave the control block
 +
unchanged after unsuccessful calls.
 +
 
 +
An appropriate extention would be for supported calls to modify the returned
 +
control block if passed invalid data, such as 8,"99:88:77" which is an invalid
 +
time.
  
 
===Data format===
 
===Data format===
Line 68: Line 77:
 
ROMs for support. Implementations should ignore unsupported subcodes and
 
ROMs for support. Implementations should ignore unsupported subcodes and
 
pass them on. Writing invalid data should be silently swallowed, what the
 
pass them on. Writing invalid data should be silently swallowed, what the
implementation does with invalid data is implementation specific.
+
implementation does with invalid data is implementation specific. Some
 +
implementations may write the data as is, so TIME$="14:90:00" sets the
 +
time to 14:90:00. Some implementations will wrap, so TIME$="14:90:00" sets
 +
the time to 15:30:00. Undefined behaviour is undefined.
  
 
===Master MOS===
 
===Master MOS===
Line 122: Line 134:
 
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 00:16, 7 January 2023 (CET)
 
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 00:16, 7 January 2023 (CET)
 
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 21:04, 7 February 2023 (CET)
 
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 21:04, 7 February 2023 (CET)
 +
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 02:34, 16 February 2023 (CET)

Revision as of 03:34, 16 February 2023

OSWORD &0F (15): Write Real-Time clock
On entry:
 XY?0=length of data at XY+1
 XY?0=3   Set alarm XY+1=3-byte BCD alarm block
 XY?0=3   Set timezone offset from XY+1="TZN"
 XY?0=5   Set from  XY+1=5-byte centisecond time
 XY?0=6   Set timezone offset from XY+1="TZN+NN" or XY+1="TZN-NN"
 XY?0=7   Set from  XY+1=7-byte BCD date block, year 1980-2079
 XY?0=8   Set from  XY+1=8-byte BCD date block with century
 XY?0=8   Set from  XY+1="hh:mm:ss"
 XY?0=11  Set from  XY+1="dd mmm yyyy"
 XY?0=15  Set from  XY+1="DDD,dd mmm yyyy"
 XY?0=20  Set from  XY+1="dd mmm yyyy.hh:mm:ss"
 XY?0=24  Set from  XY+1="DDD,dd mmm yyyy.hh:mm:ss"

The caller should simply store the length of the passed data at XY?0 and store the passed data at XY+1. The caller must not put any interpretation on the data and length it passes, that is entirely the responsibility of the code that implements the call, not the caller.

Where different subcalls have the same length byte, the calls are distinguished by the data block being either BCD or text. For instance:

  • 3,TIME - each byte is &00-&59 or &C0-&FF
  • 3,"TZN" - each byte is &40-&7F
  • 8,DATETIME - byte XY?3 is BCD value &00-&1F
  • 8,"hh:mm:ss" - byte XY?3 is printable character

On exit:

The only defined exit state is that unsupported calls should leave the control block unchanged, and known implementations leave the control block unchanged after successful calls. Known implementations also leave the control block unchanged after unsuccessful calls.

An appropriate extention would be for supported calls to modify the returned control block if passed invalid data, such as 8,"99:88:77" which is an invalid time.

Data format

The date string format is "DDD,dd mmm yyyy.hh:mm:ss". The punctuation is normally
irrelevant, the position of the component values is fixed.

7-byte BCD date block format:
 +0 year    &00-&99 year is 1980-2079
 +1 month   &01-&12
 +2 date    &01-&31
 +3 day     &01-&07 Sun-Sat or &00 for unsupported
 +4 hour    &00-&59
 +5 minute  &00-&59
 +6 second  &00-&59

8-byte BCD date block format:
 +0 century &00-&99
 +1 year    &00-&99
 +2 month   &01-&12
 +3 date    &01-&31
 +4 day     &01-&07 Sun-Sat or &00 for unsupported
 +5 hour    &00-&59
 +6 minute  &00-&59
 +7 second  &00-&59

3-byte BCD alarm block format:
 +0 hour    &00-&59 or &C0-&FF for 'any'
 +1 minute  &00-&59 or &C0-&FF for 'any'
 +2 second  &00-&59 or &C0-&FF for 'any'

Calling from BASIC

 REM X%=>control block, Y%=X%DIV256
 REM T$=string
 :
 X%?0=LEN(T$):$(X%+1)=T$
 A%=15:CALL OSWORD

Implementation

On a system without a Real Time Clock, the MOS passes OSWORD 15 to sideways ROMs for support. Implementations should ignore unsupported subcodes and pass them on. Writing invalid data should be silently swallowed, what the implementation does with invalid data is implementation specific. Some implementations may write the data as is, so TIME$="14:90:00" sets the time to 14:90:00. Some implementations will wrap, so TIME$="14:90:00" sets the time to 15:30:00. Undefined behaviour is undefined.

Master MOS

The Master MOS 3 and MOS 4 implements subcalls 8,15,24. Unimplemented subcalls are swallowed and not passed on.

Master Compact

The Master MOS 5 passes all calls to sideways ROMs.

ANFS

ANFS does not implement any OSWORD &0F calls, only OSWORD &0E calls to read the RTC.

SoftRTC

The SoftRTC module stores the time and date with the system TIME timer. It implements subcalls 7,8,11,15,20,24. The SoftRTC module included in HADFS sets the date with *SETDATE. Unimplemented subcalls are passed on.

PMS Clock

The PMS Clock ignores the subcode and instead decides what to set based on the first few characters of the data block. If there is a comma, it assumes a 24-byte time&date string. If there is a colon, it assumes an 8-byte time string.

I2C Control ROM

TicToc ROM

TicToc ignores the subcode and instead decides what to set based on the first character of the data block. If it is a digit, it assumes an 8-byte time string. If it is a letter, it assumes a 24-byte time&date string.

RISC OS

Implements subcodes 5,8,15,24. The century is read from the system configuration.

Suitable possible extensions

Calls to OSWORD &0F are simply length,string, so additional calls can be implemented for suitable parameters. These are some possibilities.

  1,nn             - ?
  2,nn,nn          - ?
  4,"yyyy"         - set year
  6,"xxxxxx"       - ?
  9,"xxxxxxxxx"    - ?
 10,"A=hh:mm:ss"   - set alarm

Notes

Have not yet found information to document implementations supporting turning alarm on/off, and reading alarm setting.

See Also