Difference between revisions of "OSWORD &8A"

From BeebWiki
Jump to: navigation, search
m (moved OSWORD 8A to OSWORD &8A)
 
m (1 revision)
 
(2 intermediate revisions by the same user not shown)
(No difference)

Latest revision as of 19:13, 8 March 2015

OSWORD &8A (138) - Set teletext pixel Dump Out 3

The control block is incorrectly defined for the OSWORD protocol,
and will work incorrectly if called from a coprocessor.
On entry:
 XY+0..1=X coord 0-1279
 XY+2..3=Y coord 0-1024
 XY?6=plot number:
  69=plot foreground
  70=invert
  71=plot background
  b7=1 to force overwriting of text
On exit:
 XY?4 =X position within cell
 XY?5 =Y position within cell
 XY?8 =text column containing cell
 XY?9 =text row containing cell
 XY?10=character containing the pixel.

See Also