Difference between revisions of "INKEY"
(Added PDP11 Unix Version 5.) |
m (Fixed broken line wrap.) |
||
Line 53: | Line 53: | ||
===Check machine type=== | ===Check machine type=== | ||
+ | Depending on what the program needs to know, [[OSBYTE &00]] is usually the | ||
+ | more appropriate call to make. | ||
Argument: -256 | Argument: -256 | ||
Returns: A value with the low byte indicating the host (I/O) machine type: | Returns: A value with the low byte indicating the host (I/O) machine type: | ||
Line 58: | Line 60: | ||
&00 RM Nimus<ref>Network User, Jan/Feb 1988, p9</ref> | &00 RM Nimus<ref>Network User, Jan/Feb 1988, p9</ref> | ||
&01 Acorn Electron OS | &01 Acorn Electron OS | ||
− | &FF BBC Micro OS 1.00/1.20/1.23 | + | &FF BBC Micro OS 1.00/1.20/1.23, Reuters OS R0.3 with *UK |
− | |||
&FE BBC Micro (American OS A1.0), Reuters OS R0.3 with *US | &FE BBC Micro (American OS A1.0), Reuters OS R0.3 with *US | ||
&FE NetBSD | &FE NetBSD | ||
Line 83: | Line 84: | ||
&Ex Spectrum | &Ex Spectrum | ||
&E0 ZX Spectrum | &E0 ZX Spectrum | ||
− | + | (INKEY-256 AND &F0)=&E0 gives TRUE for ZX Spectrum hardware | |
&Dx Amstrad 464/664/6128, etc. | &Dx Amstrad 464/664/6128, etc. | ||
− | + | (INKEY-256 AND &F0)=&D0 gives TRUE for Amstrad CPC hardware | |
&Cx Commodore 64/64+/128, etc. | &Cx Commodore 64/64+/128, etc. | ||
− | + | (INKEY-256 AND &F0)=&C0 gives TRUE for Commodore hardware | |
&Bx PDP11 Unix | &Bx PDP11 Unix | ||
&B7 PDP11 Unix Version 7 | &B7 PDP11 Unix Version 7 | ||
&B6 PDP11 Unix Version 6 | &B6 PDP11 Unix Version 6 | ||
&B5 PDP11 Unix Version 5 | &B5 PDP11 Unix Version 5 | ||
− | + | (INKEY-256 AND &F0)=&B0 gives TRUE for PDP11 hardware | |
&Ax ARM-based systems | &Ax ARM-based systems | ||
&A0 Arthur 1.20 | &A0 Arthur 1.20 | ||
Line 106: | Line 107: | ||
&AA RISC OS 5.xx | &AA RISC OS 5.xx | ||
&AE RISC OS Pyromaniac | &AE RISC OS Pyromaniac | ||
− | &AF Springboard | + | &AF Springboard - an ARM-based development system plugged into |
− | + | a PC) | |
+ | (INKEY-256 AND &F0)=&A0 gives TRUE for ARM hardware | ||
&8x Texas Instruments Calculator | &8x Texas Instruments Calculator | ||
&83 TI-83+(SE) | &83 TI-83+(SE) | ||
&84 TI-84+(SE) | &84 TI-84+(SE) | ||
− | + | (INKEY-256 AND &F0)=&80 gives TRUE for TI Calculator | |
+ | hardware | ||
&68 6809 system | &68 6809 system | ||
&63 6309 system | &63 6309 system | ||
&73 BBC BASIC on SDL abstraction from C source (ie ASC"s") | &73 BBC BASIC on SDL abstraction from C source (ie ASC"s") | ||
&57 BBC BASIC for Windows (ie ASC"W") | &57 BBC BASIC for Windows (ie ASC"W") | ||
− | &53 BBC BASIC | + | &53 BBC BASIC SDL abstraction from assembly language source |
− | (INKEY-256 AND &DB)=&53 gives TRUE for R.T.Russell's BBC BASIC for Windows/SDL/etc | + | (ie ASC"S") |
− | &4D Matrix Brandy BASIC (ie ASC"M") for all builds from | + | (INKEY-256 AND &DB)=&53 gives TRUE for R.T.Russell's |
− | + | BBC BASIC for Windows/SDL/etc | |
− | + | &4D Matrix Brandy BASIC (ie ASC"M") for all builds from v1.22.6 | |
− | + | except RISC OS. | |
− | + | ||
− | + | The known examples of German BBC MOS return X=&FF. | |
==Extensions== | ==Extensions== |
Revision as of 23:58, 18 May 2021
INKEY and INKEY$ are BASIC functions to:
- wait a specified time for a character from the input stream
- test for a keypress
- return a value indicating the machine host/operating system type
Availability | Present in all versions of BBC BASIC. | |
Syntax | <numeric> = INKEY <numeric>
|
<string> = INKEY$ <numeric>
|
Token (hex) | A6 (function)
|
BF (function)
|
Description | Reads an character from the input stream. |
Contents
Description
INKEY
and INKEY$
call OSBYTE &81.
INKEY
returns a character or -1 for no character,
INKEY$
returns a one-character string or a null string if
nothing returned.
Wait for input character
Argument: >=0 Returns: >=0, character returned -1, timed out Example: key%=INKEY(200) REPEAT:k%=INKEY(10):PROCtick:UNTIL k%>-1 Some systems allow a delay value with b15 set to return a 16-bit "deep" keyvalue distinguishing between special keys, such as function keys, and top-bit characters.[1][2] Example: REPEAT:key%=INKEY(&80C8):UNTIL key%>-1 IF key%=&190 THEN PRINT "Shift-f0 pressed"
Scan for a particular key
Argument: -1..-128, negative key number Returns: TRUE, key pressed FALSE, key not pressed
Scan for a range of keys
Argument: -129...-255, lowest internal key number to start at EOR&7F Returns: internal key number pressed, or 255 for none
Check machine type
Depending on what the program needs to know, OSBYTE &00 is usually the more appropriate call to make.
Argument: -256 Returns: A value with the low byte indicating the host (I/O) machine type: &00 BBC A/B with OS 0.10 &00 RM Nimus[3] &01 Acorn Electron OS &FF BBC Micro OS 1.00/1.20/1.23, Reuters OS R0.3 with *UK &FE BBC Micro (American OS A1.0), Reuters OS R0.3 with *US &FE NetBSD &FD Master 128 MOS 3.20/3.50 &FC BBC Micro (West German MOS) - see note &FC Windows 32 &FB BBC B+ 64/128 (OS 2.00) &FB Beos (Brandy Basic) &FA Acorn Business Computer OS 1.00/2.00 &FA Cambridge Workstation OS 2.10 &FA DOS with DJGPP extender (Brandy Basic) &F9 Communicator &F9 Linux &F8 MacOS X (Brandy Basic) &F7 Master ET MOS 4 &F7 FreeBSD &F6 OpenBSD &F5 Master Compact MOS 5 &F5 Amiga (Brandy Basic) &F4 Master 128 MOS 3.26 &F4 GNU FreeBSD (Brandy Basic) &F3 GNU (Brandy Basic) &Ex Spectrum &E0 ZX Spectrum (INKEY-256 AND &F0)=&E0 gives TRUE for ZX Spectrum hardware &Dx Amstrad 464/664/6128, etc. (INKEY-256 AND &F0)=&D0 gives TRUE for Amstrad CPC hardware &Cx Commodore 64/64+/128, etc. (INKEY-256 AND &F0)=&C0 gives TRUE for Commodore hardware &Bx PDP11 Unix &B7 PDP11 Unix Version 7 &B6 PDP11 Unix Version 6 &B5 PDP11 Unix Version 5 (INKEY-256 AND &F0)=&B0 gives TRUE for PDP11 hardware &Ax ARM-based systems &A0 Arthur 1.20 &A1 RISC OS 2.00 &A2 RISC OS 2.01 &A3 RISC OS 3.0x &A4 RISC OS 3.1x &A5 RISC OS 3.50 &A6 RISC OS 3.60 &A7 RISC OS 3.7x &A8 RISC OS 4.0x &A9 RISC OS 4.3x &AA RISC OS 5.xx &AE RISC OS Pyromaniac &AF Springboard - an ARM-based development system plugged into a PC) (INKEY-256 AND &F0)=&A0 gives TRUE for ARM hardware &8x Texas Instruments Calculator &83 TI-83+(SE) &84 TI-84+(SE) (INKEY-256 AND &F0)=&80 gives TRUE for TI Calculator hardware &68 6809 system &63 6309 system &73 BBC BASIC on SDL abstraction from C source (ie ASC"s") &57 BBC BASIC for Windows (ie ASC"W") &53 BBC BASIC SDL abstraction from assembly language source (ie ASC"S") (INKEY-256 AND &DB)=&53 gives TRUE for R.T.Russell's BBC BASIC for Windows/SDL/etc &4D Matrix Brandy BASIC (ie ASC"M") for all builds from v1.22.6 except RISC OS. The known examples of German BBC MOS return X=&FF.
Extensions
The parameter to INKEY is a 16-bit number. The standard implementation interprets that as:
<&8000 - wait for keypress &FF00+nn - scan for BBC keypress &FF00 - return host machine type
A parameter of &8000-&FEFF is undefined. Some systems extend INKEY as follows:
&FE00+nn - scan for low level DOS/Window VK_xxxx keypress (cZ80Tube, console library) &FC00+nn - scan for low level SDL1.2 SDK_xxx keypress (Brandy test builds) &8000+nn - wait for keypress, return 16-bit character code (cZ80Tube, console library)
See Also
- http://mdfs.net/Docs/Comp/BBC/Osbyte80
- http://mdfs.net/Docs/Comp/Acorn/HostVals
- http://mdfs.net/Docs/Comp/Acorn/Hosts
- What BASIC is running
- Negative INKEY numbers
References
- ↑ http://mdfs.net/Docs/Comp/KeyMap/Regular
- ↑ http://mdfs.net/System/C/Lib/console.txt
- ↑ Network User, Jan/Feb 1988, p9
Jgharston 12:27, 28 May 2009 (UTC) Jgharston (talk) 17:25, 5 July 2018 (CEST)