Difference between revisions of "Econet over IP"
m (Fixed some spelling typos.) |
m (1 revision) |
||
Line 17: | Line 17: | ||
which the 6854 ADLC puts on the wire as follows: | which the 6854 ADLC puts on the wire as follows: | ||
− | Send: | + | Send: Scout frame with packet header |
− | Receive: Scout | + | Receive: Scout fcknowledge frame |
− | Send: | + | Send: Data frame with packet data |
− | Receive | + | Receive Data acknowledge frame |
+ | |||
+ | See [[Econet packet]]. | ||
An Econet packet is sent over IP with a two-way handshake, sending a UDP | An Econet packet is sent over IP with a two-way handshake, sending a UDP | ||
Line 38: | Line 40: | ||
+-----------------------+ | +-----------------------+ | ||
|UDP Data: | | |UDP Data: | | ||
− | | Transaction Type | &01 = | + | | Transaction Type | &01 = Bradcast &02=Data packet, &03=Ack, &04=NAK, &05=Immediate, &06 Imm.Reply |
| Econet Port | From Econet packet header. Lose/gain bit 7 going from/to Econet format. | | Econet Port | From Econet packet header. Lose/gain bit 7 going from/to Econet format. | ||
| Econet Control Byte | From Econet packet header | | Econet Control Byte | From Econet packet header |
Revision as of 01:13, 8 March 2015
Contents
Econet Packet
Econet packets can be ecapsulated in UDP (User Datagram Protocol) packets to be transmitted in IP (Internet protocol) packets to be transmitted over a network with IP protocol, such as Ethernet, as done by Acorn Universal Networking.
An Econet packet looks like this:
+------+------+-----+-----+---------+------+-----------------------------+ | Dest | Dest | Src | Src | Control | Port | Data | | Stn | Net | Stn | Net | Byte | | | +------+------+-----+-----+---------+------+-----------------------------+ <-------- - - Packet Header - - ---------> <--- - - Packet Data - - --->
The Econet system sends a packet in four frames using a four-way handshake which the 6854 ADLC puts on the wire as follows:
Send: Scout frame with packet header Receive: Scout fcknowledge frame Send: Data frame with packet data Receive Data acknowledge frame
See Econet packet.
An Econet packet is sent over IP with a two-way handshake, sending a UDP data packet and waiting for an acknowledge or a negative-acknowledge UDP packet.
UDP packet
The UDP data contains an eight-byte header containing information from the Econet packet header, followed by the Econet packet data:
+-----------------------+ |UDP Header: | | Source Port | | Dest Port | &8000 for Econet-Over-IP | Length of UDP Data | | Checksum | +-----------------------+ |UDP Data: | | Transaction Type | &01 = Bradcast &02=Data packet, &03=Ack, &04=NAK, &05=Immediate, &06 Imm.Reply | Econet Port | From Econet packet header. Lose/gain bit 7 going from/to Econet format. | Econet Control Byte | From Econet packet header | Padding &00 | | Sequence Number | This increments by 4 on each transaction. | | Acks and Naks quote back the sequence they relate to. | --------------------- | | Econet | | Packet | | Data | +-----------------------+
IP Packet
The UDP packet is encapsulated in an IP packet as follows:
IP packet: +-------------------+ | IP Header: | | Version | | Header Length | | Type | | Total Length | | ID | | Fragment | | Protocol | | Header CRC | | Source Address | - site.network.net.stn | Dest Address | - site.network.net.stn | Options | | ----------------- | | IP Data: | | UDP packet | | +---------------+ | | | UDP Header: | | | | Source Port | | | | Dest Port | | - &8000 for Econet-Over-IP | | Length | | | | Checksum | | | | ------------- | | | | UDP Data: | | | | +-----------+ | | | | | Tr.Type | | | &01=Broadcast, &02=Data packet, &03=Ack, &04=NAK, &05=Immediate, &06=Imm.reply | | | Eco Port | | | From Econet packet header | | | Eco Ctrl | | | From Econet packet header | | | Padding | | | | | | Sequence | | | | | | --------- | | | | | | Econet | | | | | | Packet | | | | | | Data | | | | | +-----------+ | | | +---------------+ | +-------------------+
Broadcasts
Broadcasts just send a data block and do not wait for any acknowledgement.
Immediate Operations
The only immediate operation implemented in Acorn Universal Networking Econet over IP is MachinePeek to determine if a remote machine is present. However, immediate operations do fit into the protocol.
Coding
The Net_Tx() function in the Net library would essentially do something like the following:
DEFFNNet_Tx(Stn%,Ctrl%,Port%,Addr%,Len%,RAddr%):try=10:delay=50 REPEAT /* Prepare to send */ sock=socket(AF_INET, SOCK_DGRAM, 0); name.sin_family=AF_INET; /* Internet socket */ name.sin_port=&8000; /* Port for Econet-Over-Ethernet */ name.sin_addr.s_addr=Stn% /* Destination */ header[0]=&02 /* Econet header */ header[1]=Port% header[2]=Ctrl% header[3]=0 header[4..7]=RAddr% iov[0].base=&header /* Point to header to send */ iov[0].len=8 /* Eight bytes in header */ iov[1].base=Addr% /* Point to data to send */ iov[1].len=Len% /* Specified bytes of data */ socketwritev(sock, &iov, 1); socketclose(sock); /* Now listen for an acknowledgement */ sock=socket(AF_INET, SOCK_DGRAM, 0); name.sin_family=AF_INET; /* Internet socket */ name.sin_port=&8000 /* Port for Econet-Over-Ethernet */ name.sin_addr.s_addr=Stn% /* Who we're expecting an Ack from */ bind(sock, &name, sizeof(name)); socketread(sock, buf, buflen) socketclose(sock) IF buf[0]<>3 THEN try=try-1:IF try>0 THEN PROCdelay(delaytime) UNTIL buf[0]=3 OR try<1 IF buf[0]=3 THEN =0 :REM Ok IF buf[0]=4 THEN =&42:REM Not listening =&40:REM Network error
IP over Econet
An IP packet can be encapsulated in an Econet packet as follows:
+------+------+-----+-----+------+------+---------------+ | Dest | Dest | Src | Src | Ctrl | Port | +-----------+ | | Stn | Net | Stn | Net | Byte | &D2 | | IP Packet | | | | | | | | | +-----------+ | +------+------+-----+-----+------+------+---------------+
The Control byte determines the type of IP packet:
&81 IP &A1 ARP_REQUEST &A2 ARP_REPLY &8F IPBCAST_REQUEST &8E IPBCAST_REPLY
Jgharston 22:21, 14 May 2009 (UTC)