Difference between revisions of "OSWORD &FF"
m (Note on data length.) |
m (Slight formatting changes.) |
||
Line 1: | Line 1: | ||
[[Category:OSWORD]][[Category:Second Processors]]__NOTOC__ | [[Category:OSWORD]][[Category:Second Processors]]__NOTOC__ | ||
{{PageTitle|OSWORD &FF (255) - Data transfer over Tube}} | {{PageTitle|OSWORD &FF (255) - Data transfer over Tube}} | ||
− | ==Data transfer over Tube | + | ==Data transfer over Tube== |
+ | This OSWORD call is installed by the Z80 Tube client. | ||
On entry: | On entry: | ||
XY?0 =&0D (send block length) | XY?0 =&0D (send block length) | ||
Line 26: | Line 27: | ||
any second processor<ref name="code">[http://mdfs.net/Software/Tube/Z80/ Osword &FF code]</ref>. | any second processor<ref name="code">[http://mdfs.net/Software/Tube/Z80/ Osword &FF code]</ref>. | ||
− | ==DOS fast screen control | + | ==DOS fast screen control== |
− | + | This OSWORD call is installed by the 80x86 DOS BIOS. | |
On entry: | On entry: | ||
XY?0 =&00 (send block length) | XY?0 =&00 (send block length) | ||
Line 46: | Line 47: | ||
* Other - loop back to wait for address or termination. | * Other - loop back to wait for address or termination. | ||
− | ==See | + | ==See also== |
* [[OSWORD &05]] | * [[OSWORD &05]] | ||
* [[OSWORD &06]] | * [[OSWORD &06]] | ||
* [[OSWORD &FA]] | * [[OSWORD &FA]] | ||
* [http://mdfs.net/Docs/Comp/BBC/Oswords OSWORDs list at mdfs.net] | * [http://mdfs.net/Docs/Comp/BBC/Oswords OSWORDs list at mdfs.net] | ||
− | * [http://mdfs.net/Software/Tube/ | + | * [http://mdfs.net/Software/Tube/Utils/ OSWORD &FF source code] |
==References== | ==References== |
Revision as of 05:55, 13 December 2024
Data transfer over Tube
This OSWORD call is installed by the Z80 Tube client.
On entry: XY?0 =&0D (send block length) XY?1 =&01 (receive block length) XY!2 =I/O address XY!6 =Z80 address XY+10..11=data length, &0000=nothing to transfer XY?12 =command, 0=write to I/O, 1=read from I/O The control block is not updated on return.
The I/O address at XY!2 accesses the main I/O memory and whichever ROM happens to be paged in when the call is made - usually the current language. An updated version of the OSWORD &FF code uses the full I/O addressing range to access sideways ROMs and both banks of screen memory[1]:
&FFFFxxxx - Main memory &FFFExxxx - Currently displayed screen memory &FFFDxxxx - Shadow screen memory &FFxRxxxx - Sideways ROM/RAM R &FF8xxxxx - VDU workspace RAM
The OSWORD &FF code is available as a *runnable file that can be used with any second processor[1].
DOS fast screen control
This OSWORD call is installed by the 80x86 DOS BIOS.
On entry: XY?0 =&00 (send block length) XY?1 =&00 (receive block length)
The control block is ignored, so for speed, set XY?0=0 and XY?1=0.
Commands are sent from the 80x86 via Tube register 2. First, the address is sent, high byte then low byte. This address is updated for the data sent and wraps round from &7FFF to &4000. If the high byte is &00, no low byte is sent, and the routine finishes.
After an address has been sent, a command loop is entered. The command is sent through Tube register 2. Commands are:
- &FF - single byte read through Tube register 1 fills the following eight bytes of screen memory.
- &00 - eight bytes read though Tube register 1 fill following eight bytes of screen memory.
- Other - loop back to wait for address or termination.
See also
References
Jgharston 14:30, 26 May 2009 (UTC) Jgharston (talk) 00:06, 31 January 2016 (UTC)