Difference between revisions of "OSBYTE &6C"

From BeebWiki
Jump to: navigation, search
m (See also)
(Updated exit state.)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
[[Category:OSBYTE]]
 
[[Category:OSBYTE]]
{{PageTitle|OSBYTE &6C (108) - Main/Shadow RAM access}}
+
{{PageTitle|OSBYTE &6C (108): Main/Shadow RAM access}}
 
   On entry:
 
   On entry:
 
     X=0  Master:    Main memory appears from &3000 to &7FFF
 
     X=0  Master:    Main memory appears from &3000 to &7FFF
Line 7: Line 7:
 
         Integra-B: Display memory appears from &3000 to &7FFF
 
         Integra-B: Display memory appears from &3000 to &7FFF
 
   On exit:
 
   On exit:
     X    preserved
+
     X   master:   preserved
 +
        Integra-B  returns previous state, &00 or &01
  
 
This has immediate effect and allows the user to access the shadow display
 
This has immediate effect and allows the user to access the shadow display
Line 26: Line 27:
 
The Aries and Watford systems use [[OSBYTE &6F]].
 
The Aries and Watford systems use [[OSBYTE &6F]].
  
==See Also==
+
==See also==
 
* [[OSBYTE &49]] - Check for Integra-B shadow memory
 
* [[OSBYTE &49]] - Check for Integra-B shadow memory
 
* [[OSBYTE &6C]] - Select Master/Integra-B shadow memory
 
* [[OSBYTE &6C]] - Select Master/Integra-B shadow memory

Latest revision as of 17:05, 30 November 2022

OSBYTE &6C (108): Main/Shadow RAM access
 On entry:
   X=0  Master:    Main memory appears from &3000 to &7FFF
        Integra-B: Non-display memory appears from &3000 to &7FFF
   X<>0 Master:    Shadow memory appears from &3000 to &7FFF
        Integra-B: Display memory appears from &3000 to &7FFF
 On exit:
   X    master:    preserved
        Integra-B  returns previous state, &00 or &01

This has immediate effect and allows the user to access the shadow display memory, for instance, to load or save it or manipulate it directly. The memory that is accessed by the Master VDU drivers and displayed can set with OSBYTE &70 and OSBYTE &71.

Shadow RAM on the BBC B with the Integra-B system is also paged in with OSBYTE &6C. Note that the Integra-B functions subtly differently to the Master. If a shadow screen mode is being displayed the Integra-B functions the same as the Master. If a non-shadow screen mode is being displayed, the action is the opposite to the Master.

On the BBC B+ the displayed memory is always the bank selected with MODE or OSBYTE &72, and the user can only access the shadow memory by calling OSRDSC.

The Aries and Watford systems use OSBYTE &6F.

See also


Jgharston (talk) 01:12, 14 January 2016 (UTC)