Difference between revisions of "OSWORD &10"
m (.) |
m (.) |
||
Line 11: | Line 11: | ||
XY?0=zero if transmission failed to start | XY?0=zero if transmission failed to start | ||
− | Transmission must be polled with OSBYTE &32 (50). If the | + | Transmission must be polled with OSBYTE &32 (50). If the destination station |
− | + | is &FFFF, a broadcast will be sent, the eight bytes of data are in the control | |
− | + | block at XY+4 to XY+11. If the port number is zero, an [[Immediate operations|immediate operation]] is | |
− | + | transmitted. | |
==See Also== | ==See Also== |
Latest revision as of 18:07, 7 January 2023
OSWORD &10 (16): Network transmit
On entry: XY?0 =control byte with b7 set XY?1 =destination port XY+2..3=destination station XY!4 =buffer start address XY!8 =buffer end address XY!12 =remote address for immediate operations On exit XY?0=zero if transmission failed to start Transmission must be polled with OSBYTE &32 (50). If the destination station is &FFFF, a broadcast will be sent, the eight bytes of data are in the control block at XY+4 to XY+11. If the port number is zero, an immediate operation is transmitted.
See Also
Networking calls | |
---|---|
|
|
Jgharston 13:23, 26 May 2009 (UTC)