Difference between revisions of "OSWORD &0E"
(Corrected 8-byte BCD.) |
(Corrected 8-byte BCD.) |
||
Line 135: | Line 135: | ||
==See Also== | ==See Also== | ||
* [[OSWORD &0F]] | * [[OSWORD &0F]] | ||
− | * | + | * https://mdfs.net/Docs/Comp/BBC/Osword/RTCOswords |
[[User:Jgharston|Jgharston]] 12:56, 26 May 2009 (UTC) | [[User:Jgharston|Jgharston]] 12:56, 26 May 2009 (UTC) | ||
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 06:45, 12 April 2020 (CEST) | [[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 06:45, 12 April 2020 (CEST) | ||
[[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 23:56, 6 January 2023 (CET) | [[User:Jgharston|Jgharston]] ([[User talk:Jgharston|talk]]) 23:56, 6 January 2023 (CET) |
Revision as of 09:41, 7 January 2023
On entry: XY?0=function code XY?0=0+n use 7-bit BCD date block XY?0=8+n use 8-bit BCD date block XY?0=0 XY?0=8 Read as 25-character string XY?0=1 XY?0=9 Read as 7- or 8-byte BCD block XY?0=2 XY?0=10 Convert 7- or 8-byte BCD block at XY+1 to string XY?0=3 Read as 5-byte centisecond time XY?0=3 Read 25-character string from file server (ANFS 4.2x) XY?0=4 Read BCD clock value from file server (ANFS) XY?0=4 Return "hh:mm:ss DDD dd-mm-yy tt",CR where tt is temperature. (I2C Control ROM) XY?0=5 XY?0=6 XY?0=7 On entry: XY?0=0: Return clock value as string XY?0=8: Return clock value as string On exit: XY+0..24: CR-terminated string On entry: XY?0=1: Return 7-byte BCD clock value XY?0=9: Return 8-byte BCD clock value On exit: XY+0..6: 7-byte BCD clock value XY+0..7: 8-byte BCD clock value On entry: XY?0=2: Convert 7-bit BCD to string XY+1..7: 7-byte BCD clock value XY?0=10: Convert 8-bit BCD to string XY+1..8: 8-byte BCD clock value On exit: XY+0..24: CR-terminated string On entry: XY?0=3: Return 5-byte centisecond clock value On exit: XY?0..4: Number of centiseconds since 00:00:00 01-Jan-1900 On entry: XY?0=3: Return clock value as string from file server (ANFS 4.2x) On exit: XY+0..24: CR-terminated string On entry: XY?0=4: Return BCD clock value from file server (ANFS). On exit: XY+0..6: 7-byte BCD clock value On entry: XY?0=4: Return time, date and temperature string (I2C). On exit: XY+0..24: CR-terminated string
Data format
The date string format is "DDD,dd mmm yyyy.hh:mm:ss". The punctuation is normally irrelevant, the position of the component values is fixed. The I2C temperature string format is "hh:mm:ss DDD dd-mm-yy tt" where tt is the temperature. 7-byte BCD date block format: +0 year &00-&99 year is 1980-2079 +1 month &01-&12 +2 date &01-&31 +3 day &01-&07 Sun-Sat or &00 for unsupported +4 hour &00-&59 +5 minute &00-&59 +6 second &00-&59 8-byte BCD date block format: +0 century &00-&99 +1 year &00-&99 +2 month &01-&12 +3 date &01-&31 +4 day &01-&07 Sun-Sat or &00 for unsupported +5 hour &00-&59 +6 minute &00-&59 +7 second &00-&59 3-byte BCD alarm block format: +0 hour &00-&59 or &C0-&FF for 'any' +1 minute &00-&59 or &C0-&FF for 'any' +2 second &00-&59 or &C0-&FF for 'any'
Implementation
On a system without a Real Time Clock, the MOS passes OSWORD 14 to sideways ROMs for support.
Master MOS
The Master MOS 3 and MOS 4 implements subcalls 0,1,2. Unpatched versions always consistantly return the year in the date string as 19xx. This can be repaired with:
Read time string to T$ IF MID$(T$,14,1)<"8":T$=LEFT$(T$,11)+"20"+MID$(T$,14)
Master Compact
The Master MOS 5 implements subcall 2 to convert a BCD block to a string. It passes all other calls to sideways ROMs. If there is no response for subcall 0 and 1 it returns a default value of 31 Dec 1999, 23:59:59.
ANFS
Master ANFS 4.2x implements subcalls 0,1,3,4 and calls OSWORD 14,2 to convert the result of subcall 0 and 3 to a string. BBC ANFS 4.0x and 4.1x only implements subcall 4.
The ANFS implementation fails in a predictable manner with dates after 1996. The returned date is ((year-1981) DIV 16)*16+date and the returned year is (year-1981) AND 15. The date can be repaired across the whole date range with:
date =BCDtoBIN(returned_date) AND 31 month=BCDtoBIN(returned_month) year =(BCDtoBIN(returned_date) AND &E0) DIV 2 + BCDtoBIN(returned-year)+1900
SoftRTC
The SoftRTC module stores the time and date with the system TIME timer. It implements subcalls 0,1,2 and 8,9,10. The SoftRTC module included in HADFS only implements subcalls 0,1,2 with the date set with *SETDATE.
I2C Control ROM
The I2C Control ROM implements subcode 4 (clashing with ANFS).
RISC OS
Implements subcodes 0,1,2,3. Subcode 3 clashes with ANFS. The returned century is that set in the system configuration.
Notes
Several implementations implement clashing subcodes.
See Also
Jgharston 12:56, 26 May 2009 (UTC) Jgharston (talk) 06:45, 12 April 2020 (CEST) Jgharston (talk) 23:56, 6 January 2023 (CET)